2-Channel GSM Remote Control Unit, 4G/LTE

Two-way remote control system that uses the GSM network to drive its 2 outputs and read its 2 inputs. Control is by SMS and/or voice call. It can also send alarm notifications.

SKU 8100-TDG133_4GEAN 8057190730158Item type: Assembled

Description

Bidirectional remote control system based on the SIMCom A7682E GSM/4G module, enabling activations and controls via SMS and calls on the GSM network.

The device is compatible with 4G radio bridges, ensuring full coverage where the old 2G/3G network has been decommissioned. This GSM remote control system features two relay outputs, which can operate in monostable or bistable mode, and two opto-isolated alarm inputs.

Up to 8 numbers can be stored for sending alarms, and up to 200 numbers for the gate opening function. All system settings can be configured via SMS or, optionally, via a local PC interface using the FT782M interface.

The power supply for the GSM remote control system can range from 9 to 32 Vdc, with a maximum current draw of 1A (power supply not included). The package includes the device already assembled and tested with the A7682E GSM/4G module and a stub-style GSM antenna with connection cable.

This bidirectional remote control system allows control of boilers or other connected devices, although it does not have a specific temperature control function.

Important! To use the call service in areas covered by 4G LTE, you must have a SIM card with data and voice traffic compatible with VoLTE. Make sure, by contacting your telephone operator, that this technology is available for the SIM in use. Without this service, the remote control would only work in SMS mode.

Application Example

Example of connection to a burglar alarm

Typical Applications

In SMS mode:
โ€“ Burglar alarm systems for residential and industrial buildings
โ€“ Burglar alarm systems for vehicles
โ€“ Control of air conditioning/heating systems
โ€“ Control of pumps and irrigation systems
โ€“ Control of industrial plants
โ€“ Boiler control

In voice call / gate opening mode (Output 1):
โ€“ Gate opening
โ€“ Access control
โ€“ Reset circuits

Technical Specifications

  • GSM/4G Module: A7682E
  • Remote Control:
    • Power Supply: Between 9Vdc and 32 Vdc / 2 A (Power supply not included)
    • Uninterruptible power supply (optional, see related products): Via optional device and lithium-ion battery from 800รท1,000 mAh, it keeps the device running in the absence of mains power.

The SIMCom 4G Module

The GSM/4G module designated A7682E is manufactured by SIMCom: it is essentially a Quad-band GSM/GPRS and 4G/LTE compatible cell phone, operating on 850/900/1800/1900MHz frequencies, usable for both Internet access and voice communication, standard calls, and SMS.

It is housed in a 19.6ร—19.6ร—2.4 mm LCC+LGA package, with contacts therefore located under the body, which implies soldering with hot air or in dedicated reflow soldering machines.
The SIMCom A7682E is an LTE Cat 1 module that supports LTE-FDD/GSM/GPRS/EDGE wireless communication modes; more precisely, LTE-FDD B1/B3/B5/B7/B8/B20. It supports a maximum downlink speed of 10 Mbps and an uplink speed of 5 Mbps. In EDGE mode, speeds are Uplink/Downlink up to 236.8 kbps, and in GPRS Uplink/Downlink up to 85.6 kbps.

The A7682E adopts a form factor compatible with SIM800C, SIM868 series (GSM/GPRS modules), which allows easy migration from 2G devices to LTE ones and greatly simplifies design.
The A7682E module supports built-in network protocols TCP, IP, IPV4, IPV6, Multi-PDP, FTP, FTPS, HTTP, HTTPS, DNS, as well as the SSL communication security protocol.

It has drivers for major operating systems (USB drivers for Microsoft Windows 7/8/10, Linux, and Android). It has RIL support for Android 5.0/6.0/7.0/8.0/9.0 and firmware updates via USB/FOTA.
AT commands are compatible with SIM800 series modules, so both standard AT and most of the proprietary SIMCom enhanced AT set.
Furthermore, the A7682E integrates the main standard industrial interfaces, with powerful expandability, including numerous interfaces such as UART, USB 2.0, IยฒC-Bus, GPIO, suitable for major IoT applications such as telematics, surveillance devices, industrial routers, and remote diagnostics, etc. The module is powered by a DC voltage between 3.4 and 4.2 V (typically 3.8V) and draws a maximum of 0.8 A in transmission.

SMS Commands

Comparative table of SMS commands supported by TDG series GSM remote controls (TDG133, TDG134, TDG138, TDG139, TDG140). The TDG133 column highlighted in red indicates the commands supported by this model.

SMS Command Description Parameters TDG133 TDG134 TDG138 TDG139 TDG140 Notes
Password and Security
PWDxxxxx;pwd Change the system password xxxxx = new password (5 digits); pwd = current password โœ“ โœ“ โœ“ โœ“ โœ“ Default password 12345 on all models
Phone Number Management (main list, max 8)
NUMx+39nnnnnnnnnnn;pwd Store a phone number in the list x = position 1-8; number with international prefix; pwd โœ“ โœ“ โœ“ โœ“ โœ“ โ€“
NUMx;pwd Delete a phone number from the list x = position; pwd โœ“ โœ“ โœ“ โœ“ โœ“ โ€“
NUM?;pwd Request the list of stored phone numbers pwd โœ“ โœ“ โœ“ โœ“ โœ“ โ€“
RES;pwd Total reset: restores factory settings pwd โœ“ โœ“ โœ“ โœ“ โœ“ On TDG134 it does not delete stored numbers
Alarm Notifications per Number (SMS / ring)
SMSxxxxxxxx:ON;pwd Enable sending notification SMS to numbers in the indicated positions positions 1-8 concatenated; pwd โœ“ โ€“ โœ“ โœ“ โœ“ โ€“
SMSxxxxxxxx:OFF;pwd Disable sending notification SMS positions 1-8 concatenated; pwd โœ“ โ€“ โœ“ โœ“ โœ“ โ€“
VOCxxxxxxxx:ON;pwd Enable notification ring (short call) positions 1-8 concatenated; pwd โœ“ โ€“ โœ“ โœ“ โœ“ โ€“
VOCxxxxxxxx:OFF;pwd Disable notification ring positions 1-8 concatenated; pwd โœ“ โ€“ โœ“ โœ“ โœ“ โ€“
Input 1 Configuration (alarm)
LIV1:A / LIV1:B / LIV1:V Set the alarm condition for input 1 (high / low / change) A=high, B=low, V=change โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
INI1:mm Inhibition time for input 1 after an alarm mm = minutes 00-59, default 5 โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
TIZ1x Automatic reset of input 1 inhibition upon return x = 0/1, default 0 โœ“ โ€“ โ€“ โ€“ โœ“ โ€“
OSS1:ss Observation time (minimum alarm duration) for input 1 ss = seconds 1-59, default 1 โœ“ โ€“ โ€“ โ€“ โœ“ โ€“
TIN1A:xxxx Input 1 alarm SMS text โ€“ voltage present free text max 100 characters โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
TIN1B:xxxx Input 1 alarm SMS text โ€“ voltage absent free text max 100 characters โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
Input 2 Configuration (alarm)
LIV2:A / LIV2:B / LIV2:V Set the alarm condition for input 2 (high / low / change) A=high, B=low, V=change โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
INI2:mm Inhibition time for input 2 after an alarm mm = minutes 00-59, default 5 โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
TIZ2x Automatic reset of input 2 inhibition upon return x = 0/1, default 0 โœ“ โ€“ โ€“ โ€“ โœ“ โ€“
OSS2:ss Observation time for input 2 ss = seconds 1-59, default 1 โœ“ โ€“ โ€“ โ€“ โœ“ โ€“
TIN2A:xxxx Input 2 alarm SMS text โ€“ voltage present free text max 100 characters โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
TIN2B:xxxx Input 2 alarm SMS text โ€“ voltage absent free text max 100 characters โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
Input Configuration Query
LIV? Request the alarm level set for the inputs โ€“ โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
INI? Request the inhibition time set for the inputs โ€“ โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
OSS? Request the observation time set for the inputs โ€“ โœ“ โ€“ โ€“ โ€“ โœ“ โ€“
Alarm โ€“ SMS Repetition (firmware โ‰ฅ 2.5)
ALNn:xx Number of repeated alarm SMS to send for input n n=1/2; xx=00-99 (00=none, 99=unlimited), default 99 โœ“ โ€“ โ€“ โ€“ โ€“ Requires firmware โ‰ฅ 2.5
ALN? Request the set number of alarm SMS โ€“ โœ“ โ€“ โ€“ โ€“ โ€“ Requires firmware โ‰ฅ 2.5
Output 1 / Relay 1
OUT1:ON (OUT:ON on TDG134/TDG139) Activate output relay 1 (bistable mode) โ€“ โœ“ โœ“ โœ“ โœ“ โœ“ TDG134 and TDG139 have only one output: the command does not include the output number
OUT1:OFF (OUT:OFF on TDG134/TDG139) Deactivate output relay 1 โ€“ โœ“ โœ“ โœ“ โœ“ โœ“ โ€“
OUT1:ss (OUT:ss on TDG134) Monostable pulse: toggles relay 1 state for ss seconds ss = seconds 1-59 โœ“ โœ“ โœ“ โ€“ โœ“ โ€“
Output 2 / Relay 2
OUT2:ON Activate output relay 2 (bistable mode) โ€“ โœ“ โ€“ โœ“ โ€“ โœ“ Only on models with 2 physical outputs
OUT2:OFF Deactivate output relay 2 โ€“ โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
OUT2:ss Monostable pulse relay 2 for ss seconds ss = seconds 1-59 โœ“ โ€“ โœ“ โ€“ โœ“ โ€“
Output/Input Status
STA? (OUT? on TDG134/TDG139) Request the status of the outputs (on TDG140 the response also includes the inputs) โ€“ โœ“ โœ“ โœ“ โœ“ โœ“ Command name differs between models: STA? on TDG133/138/140, OUT? on TDG134/139
Relay State Restore After Blackout
RIPx Enable/disable restoring the relay state after a blackout x = 0 (disable) / 1 (enable), default 1 โœ“ โœ“ โœ“ โœ“ โœ“ โ€“
RIP? Request the current setting of the restore function โ€“ โœ“ โœ“ โœ“ โœ“ โœ“ โ€“
Power-On SMS
AVVx Enable/disable automatic sending of an SMS at power-on (to the first number in the list) x = 0/1, default 0 โœ“ โ€“ โ€“ โœ“ โœ“ โ€“
TSU:xxxx Set the text of the message sent at power-on free text max 100 characters, default โ€œSYSTEM STARTUPโ€ โœ“ โ€“ โ€“ โœ“ โœ“ โ€“
Automatic Periodic Report (firmware โ‰ฅ 2.5)
AUTOC:ON / AUTOC:OFF Enable/disable periodic sending of an SMS reporting input/output status โ€“ โœ“ โ€“ โ€“ โ€“ โ€“ Requires firmware โ‰ฅ 2.5
AUTOC? Request the current setting of the periodic report function โ€“ โœ“ โ€“ โ€“ โ€“ โ€“ Requires firmware โ‰ฅ 2.5
AUTOC:hh:mm:ss Set the interval for sending the periodic report hh:mm:ss, default 00:05:00 โœ“ โ€“ โ€“ โ€“ โ€“ Requires firmware โ‰ฅ 2.5
FORS:x Set the format of the report SMS x = 1 (text) / 2 (binary) โœ“ โ€“ โ€“ โ€“ โ€“ Requires firmware โ‰ฅ 2.5
Gate Opening / Call Activation Function
TAC:ss Relay activation time on call from an authorized number ss = seconds 00-59 (00 = bistable mode) โœ“ โœ“ โœ“ โ€“ โ€“ โ€“
MAC+39nnnnnnnnnnn;pwd Store a number authorized for the gate opening function only (dedicated list, max 200 numbers) number with international prefix; pwd โœ“ โœ“ โ€“ โ€“ โ€“ โ€“
DAC+39nnnnnnnnnnn;pwd Delete a number from the dedicated gate opening list number; pwd โœ“ โœ“ โ€“ โ€“ โ€“ โ€“
DAC;pwd Delete all numbers from the dedicated gate opening list pwd โœ“ โœ“ โ€“ โ€“ โ€“ โ€“
Forwarding Unrecognized SMS / Diagnostics
ECHO:x Forward SMS with unrecognized syntax to the number in position x x = position, 0 = disable โœ“ โ€“ โœ“ โ€“ โ€“ โ€“
ECHO? Request the current status of the ECHO function โ€“ โœ“ โ€“ โ€“ โ€“ โ€“ โ€“
QUAL? Request the quality of the received GSM radio signal (0-100%) โ€“ โœ“ โ€“ โ€“ โ€“ โ€“ โ€“
VER? Request the version of the installed firmware โ€“ โœ“ โ€“ โœ“ โ€“ โ€“ โ€“
Multi-Command SMS Management
RISP, Prefix that, placed at the beginning of a multi-command SMS, suppresses the related confirmation SMS โ€“ โœ“ โœ“ โœ“ โœ“ โœ“ Multiple commands in a single SMS are separated by commas
Power Failure Notification (firmware โ‰ฅ 4.0 + FT1320M accessory)
PWR0 Disable the SMS notification of power failure โ€“ โœ“ โœ“ โœ“ โœ“ โœ“ Requires firmware โ‰ฅ 4.0 and the FT1320M UPS connected
PWR1 Enable the SMS notification of power failure โ€“ โœ“ โœ“ โœ“ โœ“ โœ“ Sends an SMS on power loss and one on power restore
Anti-Jammer Master/Slave (TDG138 only)
DEV:x;pwd Set the device type x = 0 (master, default) / 1 (slave); pwd โ€“ โ€“ โœ“ โ€“ โ€“ โ€“
DEV? Request whether the module is configured as master or slave โ€“ โ€“ โ€“ โœ“ โ€“ โ€“ โ€“
ATT:tt;pwd Set the interval of periodic calls (master) or the maximum wait (slave) tt = minutes 01-59; pwd; default 50 โ€“ โ€“ โœ“ โ€“ โ€“ โ€“
ATT? Request the set interval/wait โ€“ โ€“ โ€“ โœ“ โ€“ โ€“ โ€“
TAL:xxxx Text of the alarm message sent by the slave for master no-response free text max 100 characters โ€“ โ€“ โœ“ โ€“ โ€“ โ€“
Thermostat (TDG139 only)
FUN:x Set the operating mode x = T (external thermostat) / A (automatic) / M (manual), default A โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
FUN? Request the set operating mode โ€“ โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
TEMP Request the current ambient temperature and the recorded minimum/maximum values โ€“ โ€“ โ€“ โ€“ โœ“ โ€“ Also obtainable with a missed call to the device number
TRES Reset the recorded minimum/maximum temperature values โ€“ โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
NOR:xx Set the temperature to maintain in automatic mode xx = ยฐC 00-99, default about 20-22ยฐC โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
IST:x Set the hysteresis (intervention threshold) x = 1-9 (0.1-0.9ยฐC), default 0.5ยฐC โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
IST? Request the set hysteresis value โ€“ โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
ALLMIN:yxx Set the minimum threshold of the thermal alarm y = +/-; xx = ยฐC โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
ALLMAX:yxx Set the maximum threshold of the thermal alarm y = +/-; xx = ยฐC โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
ALL? Request the set thermal alarm thresholds โ€“ โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
ALL:ON Enable the thermal alarm โ€“ โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
ALL:OFF Disable the thermal alarm โ€“ โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
INT:mm Inhibition time of the thermal alarm mm = minutes 00-59, default 5 โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
INC:mm Inhibition time of the boiler lock alarm (input 2) mm = minutes 00-59, default 5 โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
TIN:xxxx Text of the alarm SMS for input 2 (boiler lock) free text max 100 characters โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
THI:xxxx Text of the alarm SMS for exceeding the maximum threshold free text max 100 characters โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
TLO:xxxx Text of the alarm SMS for falling below the minimum threshold free text max 100 characters โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
COR:yx.d;psw Correction of the measured temperature y = +/-; x = units 0-9; d = decimal 0-9; psw โ€“ โ€“ โ€“ โœ“ โ€“ Command available with firmware โ‰ฅ 4.1
COR? Request the set temperature correction value โ€“ โ€“ โ€“ โ€“ โœ“ โ€“ โ€“
DTMF Configuration via SMS (TDG140 only)
FILx Enable/disable the filter on incoming calls for DTMF management x = 0 (answers anyone) / 1 (only numbers in list), default 1 โ€“ โ€“ โ€“ โ€“ โœ“ โ€“
SICx Require or not the password for access to DTMF commands after answering the call x = 0 (free access) / 1 (password required), default 0 โ€“ โ€“ โ€“ โ€“ โœ“ โ€“
TIM1:xx Monostable activation time of relay 1 on DTMF command xx = seconds 00-59, default 5 โ€“ โ€“ โ€“ โ€“ โœ“ โ€“
TIM2:xx Monostable activation time of relay 2 on DTMF command xx = seconds 00-59, default 5 โ€“ โ€“ โ€“ โ€“ โœ“ โ€“
TIM? Request the set times for DTMF monostable mode of both relays โ€“ โ€“ โ€“ โ€“ โ€“ โœ“ โ€“

โœ“ = command supported ย โ€ขย  โ€“ = not available on this model.

Documentation and Useful Links

Applications

FAQ

  • The device does not respond to messages. When sending the message, the LEDs give no indication of message reception
    Check that the remote control SIM has credit. If there is credit, disable RCS chat from your smartphone. To disable RCS chat, go to โ€œMessages > Messages settings > RCS chatโ€ (If this menu is not found, refer to your phoneโ€™s guide to disable the function).

Technical details

GSM/4G Module A7682E
Frequency Band LTE-FDD B1/B3/B5/B7/B8/B20/GSM/GPRS/EDGE 900/1800 MHz
Power Supply 3.4V ~ 4.2V
Typ 3.8V
Operating Temperature -40โ„ƒ ~ +85โ„ƒ
Dimensions 19.6x19.6x2.4mm
Weight 1.9 grams
LTE Cat 1 Uplink up to 5Mbps / Downlink up to 10Mbps
EDGE Uplink/Downlink up to 236.8Kbps
GPRS Uplink/Downlink up to 85.6Kbps